Sign In | Join Free | My himfr.com
Home > Drinking Water Treatment System >

500LPH Drinking Water RO System FRP Manual Control For Pure Water

    Buy cheap 500LPH Drinking Water RO System FRP Manual Control For Pure Water from wholesalers
     
    Buy cheap 500LPH Drinking Water RO System FRP Manual Control For Pure Water from wholesalers
    • Buy cheap 500LPH Drinking Water RO System FRP Manual Control For Pure Water from wholesalers

    500LPH Drinking Water RO System FRP Manual Control For Pure Water

    Ask Lasest Price
    Brand Name : Jufu
    Model Number : JFRO-500L
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability :
    Delivery Time : 2-4 weeks
    MOQ : 1 unit
    • Product Details
    • Company Profile

    500LPH Drinking Water RO System FRP Manual Control For Pure Water

    500LPH Drinking Water RO System FRP Manual Control For Pure Water


    What is Drinking Water RO System?


    Drinking water ro system is raw water by reverse osmosis system precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, In order to achieve the physical and chemical indicators of drinking water and sanitation standards, pure water is the best choice for the body to replenish water quality.


    Technical specifications of Drinking Water RO System


    Model

    JFRO-500L

    Host Size

    800x600x1600mm (can be customized)

    Power

    1.5KW

    Power Supply

    220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

    Operating Pressure

    0.8-1.2MPa

    Recovery Rate

    50%

    Designed Water Inlet

    1000L/h

    Outlet Flow

    500L/h

    Desalination Rate

    ≥99.5%

    RO Frame

    SUS304

    Membrane Size

    4040

    Membrane Elements

    DOW /Hydranautics/Troy/ Vontron (Optional)

    Number of Membranes

    2

    Raw Water Pump

    CNP/NYP/GRUNDFOS (Optional)

    Raw Water Pump

    CNP/NYP/GRUNDFOS (Optional)

    Tank Material

    SS/FRP (Optional)

    Control Valve

    Manual/Automatic

    Control Valve Brand

    FLECK/RUNXIN

    Membrane Housing

    SS/FRP (Optional)

    Pipe Material

    U-PVC, Stainless steel (Optional)


    The working process of Drinking Water RO System


    1. Preprocessing
    2. Reverse osmosis
    3. Post-processing
    4. Cleaning
    5. Electrical control



    The separation capacity of drinking water ro system membrane technology?


    Reverse osmosis is currently a relatively accurate liquid filtration technology. RO reverse osmosis membrane can retain inorganic molecules such as dissolved salts and organic compounds with molecular weight greater than 100. On the other hand, water molecules can freely pass through the RO membrane, and the removal rate of typical soluble salts is high.


    RO system failure analysis table:


    possible reasonpossible locationpressure dropProduct water flowsalt permeability
    Metal oxideThe first sectionusually increasesdeclineusually increases
    colloid foulingThe first sectionusually increasesdeclineusually increases
    foulingThe last sectionincreasesdeclineincreases

    Biofouling


    any sectionusually declineincreasesIncrease

    organic fouling


    all sectionsnormaldeclineusually increases

    Oxidizing agent (eg: Cl2)


    The first part is the most serioususually declineincreasesIncrease
    Surface wear (carbon particles,sludge)The first part is the most seriousdeclineincreasesIncrease

    Cracks in O-rings or glued


    randomusually declineusually declineIncrease
    The recovery rate is too highall partsdeclineusually declineIncrease







    FAQ:


    1. What is the membrane material of drinking water reverse osmosis system?


    Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

    Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


    2. What is the material of mechanical filter?

    Carbon steel, stainless steel, fiberglass


    3, multi-way control valve according to the control mode of those?

    Manual control valve, automatic control valve

    Multi - way control valve is divided into: filter valve and softening valve

    Automatic control valve is divided into: time type and flow type.

    Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.


    Quality 500LPH Drinking Water RO System FRP Manual Control For Pure Water for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jufu Water Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)