Sign In | Join Free | My himfr.com
Home > Drinking Water Treatment System >

500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant

    Buy cheap 500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant from wholesalers
     
    Buy cheap 500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant from wholesalers
    • Buy cheap 500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant from wholesalers

    500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant

    Ask Lasest Price
    Brand Name : Jufu
    Model Number : JFRO-500L
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability :
    Delivery Time : 2-4 weeks
    MOQ : 1 unit
    • Product Details
    • Company Profile

    500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant

    500LPH SS304 Drinking Water RO System Two-Stage Reverse Osmosis Plant


    There are three main types of failure phenomena in drinking water RO system:


    decrease in water permeability, increase in salt permeability (decreased desalination rate), and increase in pressure drop. However, there are many reasons for these failures. Try to find the problem from these failure phenomena. In order to implement the countermeasures such as maintenance and maintenance as soon as possible.



    Technical specifications of reverse osmosis water treatment equipment:


    ModelJFRO-500L
    Host Size800x600x1600mm (can be customized)
    Power1.5KW
    Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
    Operating Pressure0.8-1.2MPa
    Recovery Rate50%
    Designed Water Inlet1000L/h
    Outlet Flow500L/h
    Desalination Rate

    ≥99.5%

    RO FrameSUS304
    Membrane Size4040
    Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
    Number of Membranes2
    Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
    Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
    Tank MaterialSS/FRP (Optional)
    Control ValveManual/Automatic
    Control Valve BrandFLECK/RUNXIN
    Membrane HousingSS/FRP (Optional)
    Pipe MaterialU-PVC, Stainless steel (Optional)

    Drinking water RO system workflow:


    raw water - raw water tank - raw water booster pump - quartz sand filter - activated carbon filter - scale inhibitor dosing equipment - precision filter - first-stage high pressure pump - first-stage reverse osmosis Host - intermediate water tank - secondary high pressure pump - secondary reverse osmosis host - disinfection system - production water.


    Advantages of RO reverse osmosis membrane:


    1. Cross-flow operation process, strong anti-pollution ability, good regeneration performance and long service life.

    2. The separation precision is high, and the permeated liquid is clear and transparent, which greatly reduces the load of the subsequent refining process.

    3. Achieve high multiple concentration of fermentation broth and improve product yield.

    4. While improving the product yield, the bacteria in the fermentation broth can be recovered, bringing more profit points and environmental protection benefits to the enterprise.

    5. There is no need for filter aids in the treatment process, and there is no retention of active ingredients in the fermentation broth.

    6. Realize clean production, reduce the amount of acid, alkali and water washing, and greatly improve the biodegradability of wastewater.

    7. There is no phase change during system operation, low energy consumption and lower production cost










    FAQ:


    1, What are the inlet water quality requirements for ro water treatment system membrane components?



    Items

    NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
    Limits≤1≤5≤4≤3

    2. What is the material of ro water treatment system membrane?


    Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis


    Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


    3. RO water treatment system configuration:


    First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1


    Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.


    The arrangement of membrane components can be divided into series and parallel.


    Quality 500LPH SS304 Drinking Water RO System Two Stage Reverse Osmosis Plant for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jufu Water Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)