Sign In | Join Free | My himfr.com
Home > RO Water Treatment System >

60TPH Pure Water Treatment Plant RO Water Purification System

    Buy cheap 60TPH Pure Water Treatment Plant RO Water Purification System from wholesalers
     
    Buy cheap 60TPH Pure Water Treatment Plant RO Water Purification System from wholesalers
    • Buy cheap 60TPH Pure Water Treatment Plant RO Water Purification System from wholesalers

    60TPH Pure Water Treatment Plant RO Water Purification System

    Ask Lasest Price
    Brand Name : Jufu
    Model Number : JFRO-60T
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability :
    Delivery Time : 2-4 weeks
    • Product Details
    • Company Profile

    60TPH Pure Water Treatment Plant RO Water Purification System

    60TPH Pure Water Treatment Plant RO Water Purification System

    Product introduction of RO Water Treatment System


    The reverse osmosis water purification system uses membrane separation technology to remove charged ions, inorganic substances, colloidal particles, bacteria and organic substances in water. One-time removal of more than 98% of ions, organic matter and 100% of microorganisms in raw water, as well as a variety of dissolved and suspended chemical substances and biological substances (mainly bacteria) in water, and to asbestos, a variety of chemical substances that produce taste, color and odor, Particulate, total dissolved solids, turbidity and radium are also effective for industrial processes and drinking water production.


    Components and Principles of RO Water Treatment System


    The reverse osmosis system includes high pressure pump, reverse osmosis membrane element, pressure vessel (membrane shell), cleaning system and control instrument; the principle of reverse osmosis water treatment system is: when a pressure greater than osmotic pressure is applied on the brine side of the membrane, the water The direction of flow will be reversed, and the water in the brine will flow into the fresh water side, a phenomenon called reverse osmosis.

    Technical Specifications of RO Water Treatment System


    ModelJFRO-60T
    Host Size7200x1500x1800mm (can be customized)
    Power45KW
    Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
    Operating Pressure1.2~1.5MPa
    Recovery Rate70%
    Designed Water Inlet85t/h
    Outlet Flow60t/h
    Desalination Rate≥99.5%
    RO FrameSUS304
    Membrane Size8040
    Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
    Number of Membranes60
    Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
    High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
    Tank MaterialSS/FRP(Optional)
    Control ValveManual/Automatic
    Control Valve BrandFLECK/RUNXIN
    Membrane HousingFRP
    Number of Membrane housing10
    Pipe Material

    U-PVC/ Stainless steel (Optional)



























    Application fields of RO Water Treatment System


    1. Water for food and beverage industries
    Beverages, dairy, brewing, preparation water, low-level blending water, pure draft beer filtration
    2. Bottled and bottled drinking water
    Drinking pure water, natural water, mineral water, mineralized water
    3. Family and group water purification equipment
    High-quality water supply network systems and swimming pool water purification equipment for buildings, communities, hotels, airports, real estate properties


    Features of RO Water Treatment System

    (1) The reaction rate is fast and the processing time is short.
    (2) It has a wide range of applications, and has a good treatment effect on refractory organic compounds containing azo, carbon double bonds, nitro, and halogenated structures.
    (3) The process is simple, the service life is long, the operating cost is low, the operation and maintenance are convenient, and the treatment effect is stable.
    (4) The removal rate of chromaticity and COD is high, and the biodegradability of RO concentrated water is improved.


    Process flow of RO Water Treatment System

    Original water pump → mechanical filter (quartz sand filter)→ activated carbon filter → sodium ion exchanger (water softener)→ security filter → high pressure pump → reverse osmosis → ozone sterilizer (ultraviolet sterilizer)



    Photos of RO Water Treatment System










    FAQ:

    1. What are the inlet water quality requirements for ro water treatment system membrane components?


    Items

    NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
    Limits≤1≤5≤4≤3






    2. What is the material of ro water treatment system membrane?

    Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

    Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


    3. RO water treatment system configuration:

    First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

    Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

    The arrangement of membrane components can be divided into series and parallel.


    Quality 60TPH Pure Water Treatment Plant RO Water Purification System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jufu Water Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)