Sign In | Join Free | My himfr.com
Home > Drinking Water Treatment System >

2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production

    Buy cheap 2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production from wholesalers
     
    Buy cheap 2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production from wholesalers
    • Buy cheap 2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production from wholesalers
    • Buy cheap 2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production from wholesalers

    2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production

    Ask Lasest Price
    Brand Name : Jufu
    Model Number : JFRO-2000L
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 2-4 weeks
    • Product Details
    • Company Profile

    2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production

    2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production


    What is Reverse Osmosis Water Treatment System?


    Reverse osmosis water treatment system is usually composed of raw water pretreatment system, reverse osmosis purification system and ultra-purification post-treatment system. Membrane separation technology is applied to remove charged ions, inorganic matter, colloidal particles, bacteria and organic matter from water. Reverse osmosis membrane system is the most economical and efficient purification method to remove more than 98% ions, organic matter and 100% microorganisms (theoretically) in raw water at one time.


    Working Principle of Reverse Osmosis Water Treatment System:


    When a pressure greater than osmotic pressure is applied on the saltwater side of the membrane, the flow of water is reversed and the water in the saltwater flows into the fresh side, a phenomenon called reverse osmosis.


    Technical Specifications of Reverse Osmosis Water Treatment System:


    ModelJFRO-2000L
    Host Size2700x600x1600mm (can be customized)
    Power3KW
    Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
    Operating Pressure0.8-1.2MPa
    Recovery Rate67%
    Designed Water Inlet3000L/h
    Outlet Flow2000L/h
    Desalination Rate≥99.5%
    RO FrameSUS304
    Membrane Size4040
    Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
    Number of Membranes8
    Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
    High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
    Tank MaterialSS/FRP(Optional)
    Control ValveManual/Automatic
    Control Valve BrandFLECK/RUNXIN
    Membrane HousingSS/FRP
    Number of Membrane housing4
    Pipe Material

    U-PVC/ Stainless steel (Optional)



    Process flow of reverse osmosis water treatment system:


    Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point


    The latest development of RO membrane includes inorganic membrane, hybrid membrane and novel organic membrane. Theoretically, inorganic membrane has high ion interception performance, but its high cost and harsh preparation conditions are not conducive to industrial application. Hybrid membrane combines the advantages of organic materials and inorganic materials, which has a good application prospect in improving membrane separation performance and anti-pollution, and has great development potential, which needs further theoretical research. The preparation of new organic membranes is still in the primary stage, and the main purpose is to improve membrane flux and chemical stability, but no breakthrough has been achieved.










    FAQ:


    1, What are the inlet water quality requirements for ro water treatment system membrane components?



    Items

    NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
    Limits≤1≤5≤4≤3

    2. What is the material of ro water treatment system membrane?


    Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis


    Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


    3. RO water treatment system configuration:


    First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1


    Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.


    The arrangement of membrane components can be divided into series and parallel.

    Quality 2TPH Stainless Steel Ro Water Treatment System For Drinking Water Production for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jufu Water Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)